6.3.2.1. Sample Collection




The same procedure for well water sample collection previously described for the 300 Area was used for this area. Each well is sampled annually for semivolatiles, PCBs, pesticides, and herbicides. Also, during the second quarter, in accordance with the IEPA-approved groundwater monitoring plan, both filtered and unfiltered samples for numerous parameters (e.g., metals, chloride, sulfate) are required. Volatile organics are required to be monitored only during the second quarter.

TABLE 6.26

Groundwater Monitoring Wells: 800 Area Landfill

ID Number Well Deptha Ground Elevationb Monitoring Zonec Well Typed Date Drilled Water Elevation
800161 25 757.1 20-25/737-732 2/SS 10/92 754.53
800162 70 757.0 65-70/692-687 2/SS 10/92 718.35
800163D 154 757.1 144-154/613-603 2/SS 9/92 642.78
800171 25 749.4 20-25/729-724 2/SS 10/92 739.73
800173D 129 749.4 119-129/630-620 2/SS 10/92 632.84
800181 35 756.3 30-35/726-721 2/SS 10/92 734.65
800183D 164 755.8 154-164/602-592 2/SS 10/92 632.71
800191 15 746.0 10-15/736-731 2/SS 10/92 743.46
800192 60 746.0 55-60/691-686 2/SS 10/92 733.31
800193D 151 746.0 141-151/605-595 2/SS 10/92 632.72
800201 35 747.8 30-35/718-713 2/SS 10/92 734.42
800202 60 747.8 55-60/693-688 2/SS 10/92 718.35
800203D 126 747.8 116-126/632-622 2/SS 9/92 632.64
Note: Wells identified by a "D" are deeper wells monitoring the dolomite bedrock aquifer.
a Feet below ground.
b Feet mean sea level.
c Depth/elevation.
d Inner diameter (in.)/well material (SS = stainless steel).



Back to the Chapter Six Table of Contents